Weight and Content Uniformity of Warfarin Sodium Half Tablets
Mostafa Isbera1*, Ayat Abbood2, Wehad Ibrahim1
1Department of Pharmaceutics Faculty of Pharmacy , Tishreen University, Latakia, Syria
2Department of Quality Control , Faculty of Pharmacy , Tishreen University, Latakia, Syria
*Corresponding Author E-mail: mansouroussama@yahoo.fr
ABSTRACT:
This study aims at investigating drug content and weight of the split half tablet using tablet splitter, hand, and knife for warfarin. Warfarin sodium tablets 5 mg (brand A, brand B, brand C, brand D ) were studied, and Weight variation and drug content were analyzed for warfarin sodium in 0.1N NaOH using spectrophotometer. The percentages of each whole tablet’s or half-tablet’s drug content and weight difference from sample mean values were compared with USP specification ranges. All whole tablets and half tablets when tablet splitter was used meet the USP specification for weight and drug content ,while half tablets when hand and knife were used fail to meet the USP specification for weight and drug content. The % RSDs for drug content and weight meet the USP specification for whole warfarin sodium tablets and the half tablets which were split by tablet splitter, while halves which were split by hand and knife don't.
KEYWORDS: Warfarin sodium, tablets, weight variation, drug content, half tablets, tablet splitter.
INTRODUCTION:
Tablet splitting has become increasingly common, especially within the geriatric and psychiatric communities, as a means of reducing medication dose. Physicians frequently write prescriptions for half-tablet in order to achieve doses less than the smallest available manufactured strength. It is also recommended as a method of reducing prescription drug costs. The cost of some medication regimens can be decreased by as much as 50% [1]. There are many different ways to split tablets in half. One way is to purchase a tablet splitter from your local pharmacy. These tablet splitters are safe and easy to use. Other alternatives used are splitting by hands (for scored tablets) or with scissors (for unscored tablets), or with a kitchen knife [2]. Although cost savings maybe accomplished, problems may arise with tablet splitting such as poor cognitive function or memory, the inability of patients to effectively split tablets, and the fear of inaccurate dose. This may be clinically significant especially for drugs with a narrow therapeutic range, such as war far in sodium.
In 2002, the European Pharmacopoeia introduced a new test on the accuracy of subdivision of scored tablets [3]. Consequently, this test has become a mandatory test in many European countries in order to achieve uniform halves after tablet splitting and manufacturers following the Ph. Eur. standards that consider badly performing tablets as defective products [4,5]. The United States Pharmacopeia (USP) and the British Pharmacopoeia (BP) contain a quality control test regarding the weight uniformity of dosage units. However, they do not have tests regarding the weight uniformity of the resultant split halves or the performance of score lines of tablets. Several authors have advised to add Pharmacopoeial standards for the subdivision characteristics of scored tablets [6,7,8].
The aim of the current study is to investigate the drug content and weight of the split half tablet by tablet splitter, hand, and knife kitchen for war far in sodium tablets using the drug assay analysis. War far in sodium is a synthetic coumarin drug which depresses synthesis of prothrombin in the liver and interferes with the production of factors VII, IX, X, thereby minimizing intravascular clotting [9].
MATERIALS AND METHODS:
Warfarin sodium (5mg) tablets were studied (Table 1). This drug was chosen because it is widely used in Syria. Sodium hydroxide (Merck, Germany), Freshly distilled water, analytical balance that is accurate to 0.1 mg Mettler ToledoAj150 (Mettler Toledo, Inc., Columbus, Ohio). hardness test device (Erweka TBH 200, Germany), friability test device (Logan instruments corp, Germany), spectrophotometer (uvs-2800, labomed, Inc.).
Table 1. Description of warfarin sodium tablets studied
|
Brand |
Tablet description |
Scored |
|
A |
White, non-coated, circular tablet |
yes |
|
B |
White, non-coated, circular tablet |
yes |
|
C |
pink, non-coated, circular tablet, very small |
yes |
|
D |
pink, non-coated, circular tablet, very small |
yes |
Weight Variation:
A total of 40 whole tablets were randomly selected from each brand for war far in sodium. Ten of the 40 randomly selected tablets of war far in sodium were split in halves using tablet splitter a and 10 tablets were split by hand and 10 tablets were split by knife kitchen. Twenty whole tablets from each brand and 60 half tablets from each brand were weighted using a Mettler ToledoAj150 (Mettler Toledo, Inc., Columbus, Ohio) analytical balance. The individual weight was compared with an average weight. Not more than two of the individual weights deviated from the official standard (limit ±7.5%). Assay parameters for each drug were taken directly from USP monographs.
Calibration Curve of War far in Sodium in 0.1 N NaOH at 308 nm:
A standard curve was created for war far in sodium, using pure drug powder diluted to 5 known concentrations (range between 0.2 and 0.7 mg/100ml). These standard curves were established to verify accurate analysis of the drug.
Uniformity of Content:
First the 10 whole tablets and 30 half tablets selected from 60 halves were dissolved separately using a combination of manual agitation and sonication techniques in 50 ml of 0.1N NaOH. Then the samples were mixed well before filtration through a membrane filter. The samples of each solution were assayed for drug concentration via UV system using a Spectro UV-VIS Dual beam (UVS-2800, labomed, Inc.). The drug content was quantified by calculating the concentrations from the absorbance readings obtained through UV analysis of whole and half-tablet samples. To assess the amount and acceptability of variations in drug content and weight, several measures were calculated. The measured drug content expressed as a percent of label claim was calculated for both whole and half-tablets. Individual values for whole tablets should be in the range of 95-105% warfarin sodium (proxy USP specification for drug content). Relative standard deviation expressed as a percentage RSD, was calculated for whole tablets (drug content and weight) and for half-tablets (drug content and weight). The %RSD is widely used to assess the repeatability and precision of the assays used to analyze drug content. Individual medication lots for whole tablets are targeted to have a % RSD less than 6% (proxy USP specification for % RSD).
RESULTS AND DISCUSSION:
Calibration curve of warfarin sodium in 0.1 N NaOH at 308 nm:
A linear relationship between the absorbance and the concentration of warfarin sodium in 0.1N NAOH at 308 nm in the concentration range of 0.2-0.7 mg/100ml was observed. The regression equation is Y= 1.1576X+0.0279 and the correlation coefficients (r) of the linear regression of the calibration curves is 0.9988.
Weight Variation:
For all whole tablets studied, measured tablet weight expressed as a percent of target weight (see Table 2) was found to fall within the proxy USP specification percentage range. The weight variation increased significantly after splitting compared to the intact tablets (see Tables 3-5). Measured weight expressed as a percent of target weight for half-tablets fell within the proxy USP specification for weight for half-tablets when tablet splitter was used. Measured weight expressed as a percent of target weight for half-tablets fell outside the proxy USP specification for weight for at least (14 half for brand A, 20 half for brand B, 13 half for brand C, 7 half for brand D) half-tablets when hand was used, while the number increased when tablet was split by knife to 20 half tablets for each brand.
Table 2. Weight variation test for whole tablets.
|
Brand |
Measured weight mean (mg) N=20 |
Difference from the mean rang(mg) |
RSD(%) |
Outside of proxy USP specification |
|
A |
199.3 |
-0.98 – 1.18 |
0.41 |
0 |
|
B |
199.5 |
-1.32 – 0.88 |
0.36 |
0 |
|
C |
169.7 |
-0.92 – 1.18 |
0.42 |
0 |
|
D |
169.8 |
-0.55 – 0.35 |
0.23 |
0 |
Table 3. Weight variation test for half tablet split by tablet splitter.
|
Brand |
Measured weight mean (mg) N=20 |
Difference from the mean rang(mg) |
RSD(%) |
Outside of proxy USP specification |
|
A |
99.37 |
-3.28 – 3.43 |
2.51 |
0 |
|
B |
99.57 |
-2.98 – 2.33 |
1.17 |
0 |
|
C |
84.57 |
-3.74 – 2.83 |
2.60 |
0 |
|
D |
84.68 |
-3.18 – 3.22 |
2.80 |
0 |
Table 4. Weight variation test for half tablet split by hand.
|
Brand |
Measured weight mean (mg) N=20 |
Difference from the mean rang(mg) |
RSD(%) |
Outside of proxy USP specification |
|
A |
99.09 |
-11.2 – 11.2 |
8.88 |
14 |
|
B |
98.74 |
-12.7 – 12.6 |
12.82 |
20 |
|
C |
83.97 |
-8.61 – 9.76 |
6.91 |
13 |
|
D |
83.03 |
-11.9 – 10.2 |
7.51 |
7 |
Table 5. Weight variation test for half tablet split by knife.
|
Brand |
Measured weight mean (mg) N=20 |
Difference from the mean rang(mg) |
RSD(%) |
Outside of proxy USP specification |
|
A |
98.04 |
-13.7 – 14.2 |
14.1 |
20 |
|
B |
98.12 |
-13.8 – 14.1 |
14.5 |
20 |
|
C |
83.03 |
-17.6 – 18.5 |
16.2 |
20 |
|
D |
83.65 |
-20.2 – 21.1 |
17.1 |
20 |
Drug Content:
For all the whole tablets studied, measured drug content expressed as a percent of target drug content was found to fall within the proxy USP specification percent range (table 6). All whole tablets also met the proxy USP specification for RSD%. The measured drug content expressed as a percent of target drug content for half tablets fell within the proxy USP specification percent range when tablet splitter was used and all half tablets also met the proxy USP specification for RSD%(table 8).
The measured drug content expressed as a percent of target drug content for half tablets fell outside the proxy USP specification for drug content when hand was used. A total of 30 half of 40 half tablets (75%) fell outside of the proxy USP specification for drug content ; brand A (5 of 10 half tablets,50%) brand B (7 of 10 half tablets, 70%), brand C and D (9 of 10 half tablets in each brand, 90%) (table 8) .
The measured drug content expressed as a percent of target drug content for half tablets fell outside the proxy USP specification for drug content when knife was used. A total of 36 half of 40 half tablets 90%) fell outside of the proxy USP specification for drug content ;brand A (7 of 10 half tablets, 70%) brand B (9 of 10 half tablets, 90%), brand C and D (10 of 10 half tablets in each brand,100%) (table 9) .
All half tablets when hand and knife kitchen were used also fell outside the proxy USP specification for RSD%. Several reason could explain the observed variations in war far in half-tablet drug content. In accuracy during the tablet splitting when hand and knife were used in contrast with tablet splitter may have produced variability between tablet halves due to unequal half- tablet. The results may also have been affected by weight loss due to the powdering and fragmenting that occurred during tablet splitting using hand and knife.
Table 6. Drug content test for whole tablets
|
Brand |
Measured drug content mean (mg) N=10 |
Percent of content range (%) N=10 |
RSD(%) |
Outside of proxy USP specification |
|
A |
4.93 |
95.96-98.34 |
0.63 |
0 |
|
B |
4.92 |
97.51-98.57 |
0.58 |
0 |
|
C |
4.94 |
96.15-97.50 |
0.42 |
0 |
|
D |
4.93 |
96.15-99.14 |
0.92 |
0 |
Table 7. Drug content test for half tablet split by tablet splitter
|
Brand |
Measured drug content mean (mg) N=10 |
Percent of content range (%) N=10 |
RSD(%) |
Outside of proxy USP specification |
|
A |
2.42 |
95.95-98.34 |
0.71 |
0 |
|
B |
2.41 |
96.51-98.57 |
0.63 |
0 |
|
C |
2.41 |
96.15-100.17 |
0.89 |
0 |
|
D |
2.41 |
96.15-98.76 |
0.97 |
0 |
Table 8. Drug content test for half tablet split by hand
|
Brand |
Measured drug content mean (mg) N=10 |
Percent of content range (%) N=10 |
RSD(%) |
Outside of proxy USP specification |
|
A |
2.28 |
88.80-104.38 |
6.3 |
5 |
|
B |
2.17 |
85.41-105.79 |
9.4 |
7 |
|
C |
2.41 |
85.50-107.26 |
10.3 |
9 |
|
D |
2.41 |
85.66-107.26 |
10.4 |
9 |
Table 9. Drug content test for half tablet split by knife.
|
Brand |
Measured drug content mean (mg) N=10 |
Percent of content range (%) N=10 |
RSD(%) |
Outside of proxy USP specification |
|
A |
2.14 |
83.45-106.06 |
10.3 |
7 |
|
B |
2.11 |
83.71-108.8 |
10.8 |
9 |
|
C |
2.13 |
83.72-109.74 |
12.6 |
10 |
|
D |
2.13 |
83.45-109.60 |
12.5 |
10 |
CONCLUSION:
Tablet splitting may not have adverse clinical consequence and can reduce costs for both patients and institutions [2], but using a whole tablet is the safest way to ensure accurate dosing. However, not all formulations are suitable for splitting, and even when they are, it may lead to dose deviations. This could have serious clinical consequences for medications with a narrow therapeutic-toxic range such as war far in sodium. the results obtained in this study have shown that half-tablets for war far in sodium could pass both the weight uniformity and content uniformity while half- tablets fell outside the USP specification proxy for weight and drug content when hand or knife was used, so the use of tablet splitter when splitting cannot be avoided and it is superior to hand or knife splitting. Manufacturers should also investigate the physical factors such as tablet, size, shape, friability and hardness that may play an important role in achieving both weight and content uniformity.
ACKNOWLEDGEMENTS:
Author would like to thank Dr. Oussama Mansour , Faculty of Pharmacy- Alandalus University-Syria, for his scientific contribution and guidance not to forget the language assistance provided by Mr. Ayham Aljghami, instructor at The Higher Institute of Languages-Tishreen University-Syria, during the writing process.
REFERANCES:
1. Mcdevitt J T, Gurst A H. Accuracy of tablet splitting. Pharmacotherapy. 1998; 1: 193-197.
2. Verrue C, Mehuys E, Boussery K, Remon J, Petrovic M.Tablet-splitting: a common yet not so innocent practice. J Adv Nurs 2011; 67: 26 –32.
3. European Pharmacopoeia Suppl. 4.1. Tablets, Monograph 047- 078. Council of Europe, Strasbourg, France; 2002.
4. Van Santen E, Barends DM, Frijlink HW. Breaking of scored tablets: a review. Eur J Pharm Biopharm 2002; 53:139 –143.
5. Rodenhuis N, De Smet PA, Barends DM. Patient experiences with the performance of tablet score lines needed for dosing Pharm. World Sci2003; 25: 173–176.
6. Green G, Berg C, Polli J, Barends D. Pharmacopeial standards for the subdivision characteristics of scored tablets. Pharmacopeial Forum 2009; 35: 1598–1603.
7. Rosenberg JM, Nathan JP, Plakogiannis F. Weight variability of pharmacist dispensed split tablets. J Am Pharm Assoc 2002; 42: 200 –205.
8. ZAID A N et al. weight and content uniformity of lorazepam half-tablets: A study of correlation of a low drug content product. Saudi Pharmaceutical Journal2013;1: 71-75.
9. Lopez L. Prescribing Individualized dosing of Warfarin? Why so complicated?. Drugs and Therapy Bulletin 2010; 24.
Received on 02.11.2015 Modified on 21.11.2015
Accepted on 05.12.2015 © RJPT All right reserved
Research J. Pharm. and Tech. 9(3): Mar., 2016; Page 215-218
DOI: 10.5958/0974-360X.2016.00039.1